Fire Alarm Manual Pull Station Height Code

Manual pull station, K Class fire extinguisher and suppression system cabinet. A minimum of one (1) set of specifications shall be provided. Manufacturer documentation for all parts and materials used in the project. Plans shall indicate the interconnection to the building fire alarm system; 20. Most fire alarm bells should be mounted at heights that place their tops above the floor at a height of at least 90 inches, or 7 1/2 feet, leaving at least 6 inches between the ceiling and the bell. Exceptions to standard fire alarm bell mounting heights must account for audibility in fire alarm systems. Jun 27, 2018 The requirements for manual pull stations as per NFPA 72 are pretty trivial and straight-forward. NFPA 72 requires that manual pull stations be installed within 60 inches of the exit doorway of each exit, mounted between 42 inches and 48 inches to the center of the handle, and, among other things, be red in color.

  1. Fire Alarm Manual Pull Station Height Code California
  2. Fire Alarm Manual Pull Station Height Code California

Enter any high occupancy building in the country and you may have noticed a red box with the word “Fire” or “Fire Alarm” written on its front cover. You may have seen them, but do you know what their main purpose is and more importantly, how to use them?

If you’re not familiar with manual pull stations, by reading this article you will gain a better understanding of how they operate and when they are to be used in fire emergency situations.

Fire Alarm Manual Pull Station Height Code

Errata: The line item for the “.030 Ampere/16AWG” entry is shown as “150 feet” in Table 5 of the FA-1000 installation manual. We have converted the “229 meter” entry on the line next to it to reflect the corrected Imperial measurement of “751”. End-of-Line Resistors may be mounted in a properly identified common termination box or inside the fire alarm system’s. Manual Fire Alarm Boxes (Pull Stations) – The height of the manual fire alarm boxes shall be a minimum of 42 inches and a maximum of 54 inches measured vertically, from the floor level to the activating handle or lever of the box. Manual fire alarm boxes shall be red in color.

Manual Pull Station Myth Busted!

If you’re in the fire alarm business, you are very familiar with the manual pull station. They seemingly jump out at you when watching movies, don’t they?

You’ve probably seen McGyver or some other show where a spy or bank robber pulls a station to distract or evacuate a building. The clincher is when this is done on a Hollywood movie set, it activates the building’s fire sprinkler system… This is simply a big myth.

Height

Sure it looks cool on T.V. or in the movies but it’s stretching reality to its limits.

Unbeknown to most people, a fire alarm pull station cannot soak a building’s inhabitants with the sprinkler system. Let’s put this myth to rest, shall we? It is impossible to activate a water-filled sprinkler system with a manual pull station.

Yes, the building’s fire alarm system “is” tied into the sprinkler system, but in most cases, it is for monitoring purposes only and has nothing to do with sprinkler “activation”. It actually works the other way around. In reality, the sprinkler system activates the electronic fire alarm system, not visa-versa. So, the next time you see this happen in an action film, write it off as “bad research” or ignorance on the part of the movie producer.

Exceptions To This Rule

There “are” manual pull stations specifically installed to activate kitchen hood systems, CO2, Halon, and dry systems in places that require a fire retardant agent, so there is a bit of truth to this myth. In most cases, you will find these systems located in kitchens, computer rooms, document storage facilities or other areas that require immediate fire protection, but won’t cause water damage.

Many of these types of systems work by smothering the fire and reducing, replacing or removing oxygen from the air. In these types of systems, occupants must be fully trained and educated in what to do in case a fire breaks out and on the proper evacuation procedures required.

Typical Locations of Manual Pull Stations In Commercial Buildings

According to most fire and building codes, including NFPA72 and the International Building Codes, manual pull stations shall be installed at or near all building exits. Without going into specific details, we will say that in the NFPA72, manual stations are to be installed within five feet from a single door exit and if the door is wider than specified for a single opening, two stations must be installed (this information can be found in NFPA72).

In high-rise buildings you will also find them near all stairway exit doors and even in elevator lobbies.

How To Operate A Manual Pull Station

Typically, there are two types of stations. One is called a single action, the other a double or dual action. On a dual action station, one is required to either lift a cover or push in a latch to enable the “pulling” action of the pull station.

In many jurisdictions the dual action pull station is required to prevent anyone from “accidentally” moving the pull station into an alarmed state. In other words, if a pull station is triggered on a dual-action, it is highly likely that the triggering was done intentionally.

When Is It Appropriate To Use A Manual Pull Station?

For all practical purposes, the pull station is used to manually activate a fire alarm if the fire has not yet reached the sensing range of automatic fire detection devices, such as smoke or heat detectors.

It is done by pulling a door or level down or away from the wall-base of the station. This pulling action then actuates a switch located within the manual pull station, which in turn triggers the building’s fire alarm system.

The reasoning behind locating pull stations near all building exits is so that the person activating the alarm is moving out and away from the building at the time they are activating the fire alarm system.

Please note that there are other rules concerning locations in long hallways. For more information or more intricate details, contact your local fire marshal’s office or purchase the one of the fire alarm code/handbooks.

Is There Ever A Bad Time To Activate A Manual Pull Station?

As long as there are signs of fire present, anytime is a good time. On the other hand, if one were to pull one of these stations just to get someone’s attention or to play a “joke”, then it’s not only ethically wrong to do so, but is illegal and considered a felony. It can lead to thousands of dollars in fines and even land someone in jail.

When it comes to perpetrators “purposefully” activating false fire alarms, the courts (and fire officials) look at this action as a form of aggression towards the safety and well-being of others lives and they don’t take this action lightly. There is a good chance that if one gets caught, he (or she) will get maximum penalties for committing this crime.

Fire Alarm Manual Pull Station Height Code

If you are thinking you won’t get caught, think again…

Case Of A Juvenile Delinquent’s Idiotic Reasoning

A couple of years ago, a middle school called us out to reset a pull station because they misplaced their alarm reset keys.

By the time we arrived, the campus police had already apprehended a girl who pulled the manual station because she was about to take a test and wanted extra time to study for the test.

Thinking that this ordeal would temporarily suspend classes and use up much of the time it would to take the test, she decided to disrupt the entire school by pulling the alarm. Little did she know there were hidden cameras at every exit recording her every move. Kids, if you are reading this article, this is a very serious matter and chances are, YOU WILL GET CAUGHT.

Sure, little practical jokes can be fun at times, but this is no laughing matter. Lives may be lost if a fire department is responding to a false alarm while others are in desperate need of help from their local fire department.

Fire Alarm Manual Pull Station Height Code California

In Closing…
We hope you have learned what a manual pull station and its use is for and hope that you come back for more tips on commercial fire alarm systems. If you would like to stay up-to-date and informed, please feel free to fill out the form in the upper right hand corner of this page and an automatic email will be sent to you as soon as we place a new article on our website.

Thanks for visiting the Platinum Fire Protection website.

Fire Alarm Manual Pull Station Height Code California

Filed Under: Initiating Devices
Tagged: Fire Pull Stations, How To Activate A Fire Alarm Pull Station, Illegal Activities Concerning Fire Alarm Systems, Initiating Devices, Manual Building Evacuation, Manual Fire Alarm Activation, Manual Pull Station, Manual Pull Station Locations, Manual Pull Stations